0908
Model # AC-G0005
6500 Surge Watts / 6000 Running Watts
ELECTRIC START PORTABLE GENERATOR
INSTRUCTION MANUAL
Thank you for purchasing this high quality ACDelco Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator.
This manual provides important information on properly operating and maintaining this ACDelco Model AC-G0005 6500 Surge Watts / 6000 Running
Watts Electric Start Portable Generator. Every effort has been made to ensure the accuracy of this manual.
We reserve the right to change this
product at any time without prior notice.
This manual contains important information regarding safety, operation, maintenance and storage of this product. Before use, read carefully and
understand all warnings, cautions, instructions and labels. Failure to do so could result in serious personal injury, property damage or even death.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
STOP!
DO NOT RETURN THIS GENERATOR TO THE RETAILER.
Questions? Problems? CONTACT BUFFALO TOOLS.
If you experience a problem or need to return this generator for repair, please fill out a RGA form by visiting our web site, http://www.buffalotools.com
Or, call our customer help line at
1-866-460-9436, Monday-Friday, 8 AM - 4 PM Central Time. A copy of the sales receipt is required.
c/o
New Buffalo Corporation
1220 North Price Road
St. Louis MO 63132
Phone: 866-460-9436
www.buffalotools.com
Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator
1
Page view 0
1 2 3 4 5 6 ... 34 35

Summary of Contents

Page 1 - INSTRUCTION MANUAL

0908 Model # AC-G0005 6500 Surge Watts / 6000 Running Watts ELECTRIC START PORTABLE GENERATOR INSTRUCTION MANUAL Thank you for purchasing this hi

Page 2 - FEATURES:

GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator. (1) 120/240 Volt AC Outlet - Use

Page 3 - TABLE OF CONTENTS

PREPARING THE GENERATOR FOR USE Using this Generator for the First-Time STOP! The following section describes the required steps for prepar

Page 4

Step 2 - Add Gasoline Gasoline and gasoline fumes are highly flamma

Page 5

Step 3 - Ground the Generator Failure to properly ground this gene

Page 6

Step 2 - Verify Gas Level Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the t

Page 7

To start this generator: 1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in

Page 8

USING THE GENERATOR After the engine has been running for several minutes, electrical devices may be connected to this generator. AC Usage Electri

Page 9 - PACKAGE CONTENTS

Electrical Device Rated (Running) Watts Additional Surge Watts air compressor (1 HP) 1500 3000 air compressor (1 - 1/2 HP) 2500 2500 airless spr

Page 10 - GENERATOR COMPONENTS

Do not connect 50Hz or 3-phase loads to this generator. Figure 8

Page 11 - STOP!

3. Start this generator. 4. Carefully connect the free end of the negative wire to the negative side of the outlet on this generator. 5. When disconne

Page 12 - Step 2 - Add Gasoline

ACDelco Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator FEATURES: • 6500 Surge Output • 6000 Running Watts •

Page 13

Recommended Maintenance Schedule Each Use Every Month or Each 20 Hrs Every 3 Months or Each 50 Hrs Every 6 Months or Each 100 Hrs Every Year or E

Page 14 - STARTING THE GENERATOR

Changing/Adding Oil The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is low, add oil until the

Page 15

6. Soak the dry sponge-like elements in engine oil. Squeeze out any excess oil. The engine will smoke during initial startup if too much oil is left i

Page 16 - USING THE GENERATOR

Spark Plug Maintenance The spark plug is essential for proper engine operation. The spark plug should be intact, free of deposits, and properly gappe

Page 17

STORAGE/TRANSPORT PROCEDURES Never place any type of storage cover

Page 18 - DC Usage

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 25 TROUBLESHOOTING IMPORTANT: If trouble persists, call our c

Page 19 - MAINTENANCE/CARE

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 26 SPECIFICATIONS ACDelco Model AC-G0005 6500 Surge Watts / 60

Page 20

EXPLODED VIEW AND PARTS LIST Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 27

Page 21

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 28 PARTS LIST Item Part Qty Description Item Part Qty

Page 22 - Fuel Filter Cup Cleaning

MODEL AC-G0005 6500 SURGE WATTS / 6000 RUNNING WATTS ELECTRIC START PORTABLE GENERATOR WIRING DIAGRAM Model AC-G0005 6500 Surge Watts / 6000 Run

Page 23

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 3 TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABEL

Page 24 - STORAGE/TRANSPORT PROCEDURES

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 30 NOTES:

Page 25 - TROUBLESHOOTING

WARRANTY LIMITED WARRANTY for ACDelco Generators from New Buffalo Corporation. Remember to save your receipt and to accurately fill out and mail you

Page 26 - SPECIFICATIONS

PORTABILITY KIT INSTALLATION The manufacturer recommends when using your ACDelco generator for recreational or utility functions that you pro

Page 27 - EXPLODED VIEW AND PARTS LIST

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 33

Page 28 - PARTS LIST

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 34

Page 29 - WIRING DIAGRAM

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 35 (A

Page 30

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in

Page 31 - WARRANTY

Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are cert

Page 32

Powerful Voltage: This generator produces powerful voltage, which can result i

Page 33

Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator 7

Page 34

In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator. Model AC-

Page 35 - (AC-G0005-0908)

PACKAGE CONTENTS The following items are supplied with this ACDelco Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Gene